AUTOMATIC MAINS FAILURE UNITS
DKG-309
* Available with J1939 or magnetic pickup input
* Mains / genset voltage inputs: 3 / 1
* Genset current inputs: 1
* Configurable digital inputs: 5
* Configurable analogue temperature,
oil pressure and fuel level inputs
* Configurable digital outputs: 2
* Total digital outputs: 6
* Triple language support
* Customer logo display capability
* Available with J1939 or magnetic pickup input
* Mains / genset voltage inputs: 3 / 3
* Genset current inputs: 3
* Configurable digital inputs: 7
* Configurable analogue temperature,
oil pressure and fuel level inputs
* Configurable digital outputs: 2
* Total digital outputs: 6
* Output expansion capability
* Triple language support
* Customer logo display capability
* Configurable from front panel
* 3 level password support
* Dual genset mutual standby operation
* Genset KW and PF measurement
* Battery backed-up real time clock,
* Weekly operation schedule programs
* Built-in daily, weekly, monthly exerciser
* 100 events with time stamp and
measurements
* Serial RS-232 port
* GSM SMS message sending on fault
* Modem calls on fault
* MODBUS communications
* MS-Windows remote monitoring SW
* Dimensions: 165 x 125 x 48 mm (WxHxD)
* Configurable from front panel
* 3 level password support
* Dual genset mutual standby operation
* Genset KW and PF measurement
* 100 events with measurements
* Logic level serial port
* GSM SMS message sending on fault
* MODBUS communications
* MS-Windows remote monitoring SW
* Dimensions: 96 x 96 x 53 mm (WxHxD)
DKG-109DKG-547
* Dual genset mutual standby operation
* Genset KW and PF measurement
* Battery backed-up real time clock,
* Weekly operation schedule programs
* Built-in daily, weekly, monthly exerciser
* 200 events with time stamp and
measurements
* Serial RS-232 port
* GSM SMS message sending on fault
* Modem calls on fault
* MODBUS communications
* MS-Windows remote monitoring SW
* Dimensions: 202x148x48mm (WxHxD)
* J1939 CANBUS ECU control and monitoring
* J1939 ECU warnings displayed as text
* Mains / genset voltage inputs: 3 / 3
* Genset current inputs: 3
* Configurable digital inputs: 8
* Configurable analogue temperature,
oil pressure and fuel level inputs
* Configurable digital outputs: 2
* Total digital outputs: 6
* Output expansion capability
* Triple language support
* Customer logo display capability
* Configurable from front panel
* 3 level password support
DKG-543
* Dual genset mutual standby operation
* Genset KW and PF measurement
* Battery backed-up real time clock,
* Weekly operation schedule programs
* Built-in daily, weekly, monthly exerciser
* 100 events with time stamp and
measurements
* Serial RS-232 port
* GSM SMS message sending on fault
* Modem calls on fault
* MODBUS communications
* MS-Windows remote monitoring SW
* Dimensions: 202x148x48mm (WxHxD)
* Mains / genset voltage inputs: 3 / 3
* Genset current inputs: 3
* Configurable digital inputs: 8
* Configurable analogue temperature,
oil pressure and fuel level inputs
* Configurable digital outputs: 2
* Total digital outputs: 6
* Magnetic pickup input
* Output expansion capability
* Triple language support
* Customer logo display capability
* Configurable from front panel
* 3 level password support
DKG-509
* Available with J1939 or magnetic pickup input
* Mains / genset voltage inputs: 3 / 3
* Genset current inputs: 3
* Configurable digital inputs: 7
* Configurable analogue temperature,
oil pressure and fuel level inputs
* Configurable digital outputs: 2
* Total relay outputs: 6
* Output expansion capability
* Triple language support
* Customer logo display capability
* Configurable from front panel
* 3 level password support
* Dual genset mutual standby operation
* Genset KW and PF measurement
* Battery backed-up real time clock,
* Weekly operation schedule programs
* Built-in daily, weekly, monthly exerciser
* 100 events with time stamp and
measurements
* Serial RS-232 port
* GSM SMS message sending on fault
* Modem calls on fault
* MODBUS communications
* MS-Windows remote monitoring SW
* Dimensions: 190 x 135 x 48 mm (WxHxD)
DKG-545
* Dual genset mutual standby operation
* Genset KW and PF measurement
* Battery backed-up real time clock,
* Weekly operation schedule programs
* Built-in daily, weekly, monthly exerciser
* 100 events with time stamp and
measurements
* Serial RS-232 port
* GSM SMS message sending on fault
* Modem calls on fault
* MODBUS communications
* MS-Windows remote monitoring SW
* Dimensions: 202x148x48mm (WxHxD)
* Mains / genset voltage inputs: 3 / 3
* Load current inputs: 3
* Configurable digital inputs: 9
* Configurable analogue temperature,
oil pressure and fuel level inputs
* Configurable digital outputs: 7
* Total digital outputs: 7
* Magnetic pickup input
* Output expansion capability
* Triple language support
* Customer logo display capability
* Configurable from front panel
* 3 level password support